Event Types
4 minute read
Filter Type Name | Severity | Message | Description |
---|---|---|---|
All Gateways Disconnected | WARNING | This event will be triggered if an edge node loses connectivity to all it’s available gateways. | |
All Peers Disconnected | WARNING | This event will be triggered if a node is configured as a gateway an it lose connectivity to all it’s configured edge nodes. | |
Certificate Expiring | WARNING | Alerts when a certificate uploaded via Portal → Certificates is about to expire in less than three months. | |
Cluster Failover | INFO | Node is the active cluster member | Sent by a node when it claims the active role. |
Cluster Failover | Info | Node is no longer the active cluster member | Sent by a node when it releases the active role. |
Connection Flapping | WARNING | Alerts when a node disconnects and reconnects 10 times within 5 minutes. A follow up alert will be sent after each subsequent 120 disconnect/reconnects. | |
Connection Flapping | INFO | This alert will be sent when a node’s “Connection Flapping” issue has been resolved. | |
Connection Timeout | ERROR | Alerts when a node does not reconnect after a profile update has been pushed to the node. | |
Data Plane Disruption | WARNING | This event will be triggered if a data plane tunnel is terminated unexpectedly. | |
Data and Control Plane Disruption | ERROR | Data and Control plane connection is up/down | Generated when a node cannot establish a connection to the Trustgrid control plane and all its configured data plane gateways. If clustered this will mark the node as unhealthy triggering a cluster failover |
Data Plane Disruption | WARNING | Gateway nodename removed from the domain | If a node acting as a gateway (public, private or hub) is disabled or the gateway service is disabled all other nodes in the domain will log this event. |
DNS Resolution | ERROR | DNS resolution failed/re-established | Once per hour the node will attempt to resolve a trustgrid.io DNS address using the configured DNS servers. This event is triggered if the node is unable to resolve the requested address. |
Gateway Connectivity Health Check | CRITICAL | Alerts when an edge node is unable to communicate with a gateway node. | |
Gateway Connectivity Health Check | INFO | Alerts when an edge node reestablishes connectivity to a gateway node after a failure is reported. | |
Gateway Ingress Limit Reached | ERROR | Alerts when a gateway node’s ingress limit is above 95 percent utilization for two minutes straight. | |
Metric Threshold Violation | ERROR | Alerts when a node cpu, ram, disk, or latency configured metric threshold is violated. | |
Metric Threshold Violation | INFO | Alerts when a previously reported threshold violation has been cleared. | |
Network Error | CRITICAL | Stale ARP detected | Alerts when a stale ARP entry is detected for a node’s cluster IP. |
Network Error | WARNING | Interface {OS interface name} is running with half-duplex | Alerts if an interface has been detected running at half-duplex. This is almost always a result of a failure to auto-negotiate the speed/duplex and can result in poor performance. |
Network Health Check | ERROR | Interface {OS interface name} is down / All interfaces are up | Generated when link is lost on a configured interface. This is generated even if the interfaces is set with the “Ignore Health Check” setting enabled. Note: Interfaces with APIPA addresses are ignored. |
Node Connect | INFO | Alerts when a node connects to the control plane. | |
Node Disconnect | WARNING | Alerts when a node disconnects from the control plane. | |
Node Delete | WARNING | Node deleted | Event generated whenever a node is deleted |
Node Stop Error | ERROR | Failed to stop the Node service cleanly | Indicates that the Trustgrid service did not stop normally prior to this instance starting |
Order Created | INFO | Alerts when a new provisioning order has been created. | |
Order Commented | INFO | Alerts when a provisioning order case has been commented. | |
Unauthorized IP | WARNING | Alerts when a node’s public IP has been locked but the connection to the control plane comes from a different IP. | |
Deregister | INFO | Device was deregistered from the console | Event is sent if a user with console access runs the deregistration process |